Spray Foam Insulation for Metal Buildings: A Guide for East Metro Detroit Business Owners
Own a steel shop or warehouse? Then you’ve likely walked in on a cold morning to find the roof panels wet and dripping on whatever you left under them. Six months later it’s the opposite problem, and by lunchtime the place feels like an oven. Spray foam insulation for metal buildings can sort out both. The catch is picking a foam type and thickness that suits what really goes on inside.
Koala Insulation of East Metro Detroit works on metal buildings all over Oakland and Macomb counties. Some are big light-industrial units, some are a guy’s steel garage out back. Below we’ll cover why steel buildings sweat and which foam holds up on steel in our climate. There’s also a section on scheduling the work so your business keeps running, plus what code asks for once the foam’s in.
Where You’ll Find Metal Buildings in East Metro Detroit
Most of them are commercial. Warren, Sterling Heights and Madison Heights have whole industrial stretches lined with pre-engineered steel boxes, the kind you stop noticing after a while. Auto suppliers work out of them. So do fab shops and contractors’ yards. A lot of these went up with a thin faced fiberglass blanket against the roof deck, and some got nothing at all.
Ready to start your insulation project?
Further out in Shelby Township and Macomb Township, it’s more often a steel garage or workshop behind a house. Smaller job. The condensation and the summer heat are exactly the same, though.
Why Metal Buildings Sweat
Steel moves heat fast. On a cold night the inside of a roof panel drops close to the outdoor temperature, and any warm, damp air in the building condenses right on it. Honestly, it takes less moisture than people think. Put a crew to work, fire up a gas heater, let a few trucks track slush in, and you’ve got drips by morning.
Where does that water go? Onto your stock, mostly, and your machines. Give it a few winters and the fasteners and purlins start rusting from the back side, where nobody looks. Any old blanket insulation up there gets soaked too. Wet fiberglass is close to useless.
A wood frame can take on some moisture and dry out later on. Steel can’t. As a Walls & Ceilings analysis of metal building insulation puts it, a metal assembly only gets to dry in one direction. So the insulation’s real job is keeping warm, damp air from ever touching the cold steel.
The Summer Side of the Problem
Then summer shows up. Detroit gets muggy, and a bare steel roof sits there cooking from about eleven onward. That heat comes straight down onto the floor. Your crew feels it first. The rooftop units barely shut off, and if you’re storing anything that doesn’t like heat, well, it’s not having a good time.
Spray closed-cell foam on the underside of the deck and a lot less of that heat makes it through. It holds heat in during winter too. Funny enough, owners of buildings that are used all year tend to mention the cooler summers before they mention the heating bill.
Open Cell vs Closed Cell Spray Foam Insulation for Metal Buildings
For bare steel in Michigan, it’s almost always closed cell.
Per inch, closed-cell foam lands somewhere around R-6 or R-7. Moisture doesn’t move through it easily either. Get about two inches on and the foam acts as its own vapor retarder, which means the damp air inside never touches the cold panel in the first place. Bonus you might not expect? Thin panels get a bit stiffer and rain on the roof gets a lot quieter.
Open-cell is lighter and cheaper. The trouble is vapor walks right through it, and on cold steel that vapor condenses on the back of the panel, behind the foam where you can’t see it. Walls & Ceilings ran the numbers on open-cell foam over a metal wall in a cold climate, and it held way more moisture than it should, at least without an interior vapor barrier added on. Closed-cell foam didn’t need one.
Yes, closed cell costs more per inch. But on steel, the cheap option that leaves the building sweating tends to cost more down the road in rusted fasteners and ruined stock.
How Much Foam Does a Metal Building Need?
Depends what you do in there.
Say it’s cold storage and all you care about is the dripping. Two inches of closed-cell (call it R-12 to R-14) might do the job. Heated shops are different. If people are in there working through January, three inches or more is usually worth it, and that gets you into the R-18 to R-21 range. We’d normally put more on the roof than the walls, since the roof’s where you lose heat in winter and pick it up in summer.
One tip for when the quotes come in. Get the roof and wall thickness broken out on their own lines. If a quote just says “spray foam, whole building,” you’ve got nothing to hold it up against.
Planning the Work Around Your Business
Here’s where commercial jobs really differ from residential ones.
While the foam’s going on, nobody without protective gear can be in that area, and it has to air out before your people come back in. So for a business it really comes down to timing. A lot of owners just have us do one bay at a time. Others save it for a long weekend or a shutdown they already had planned. On bigger buildings the roof sometimes gets done in sections around production.
Sort these out before the crew shows up:
- Which areas can be shut down, and for how long
- Stock and equipment that needs to be moved or covered
- Lift access for tall ceilings, and room to get the rig in
- HVAC and exhaust fans off, or closed off from the work area
- Cleanup on panels that are rusty or oily, and pulling down any old blanket insulation
Old fiberglass that’s sagging or wet? Then insulation removal comes first. Foam needs bare, clean steel to grab onto.
What Building Code Requires Once the Foam Is On
Spray foam in occupied space generally has to be covered with an approved thermal barrier, and half-inch drywall is the usual one. Some codes let a tested coating stand in for that. Commercial buildings get inspected under the commercial code, so budget for the covering from the start.
Ask the installer which covering your building needs and whether it’s in the quote. Find out who’s pulling the permit, too.
When Should You Hire a Professional?
A few signs a metal building needs attention:
- Water dripping from the roof on cold mornings
- Rust on fasteners, purlins or the underside of the deck
- Frost on the inside of the panels in winter
- A building that’s too hot to work in by mid-afternoon in summer
- Torn, sagging or wet blanket insulation
Insulating a whole building isn’t a DIY job. Closed-cell foam has to go onto clean, dry steel inside the manufacturer’s temperature range, and in winter that can mean heating the space first. Then there’s the spray rig, the lifts, the protective gear and the ventilation. Our guide on how to judge spray foam installers explains what a good installation should look like.
Running a warehouse or larger facility? Take a look at our commercial insulation services. If you’d like a measured quote on your own building, request a free estimate from Koala Insulation of East Metro Detroit.
The Koala Insulation Process
Every metal building job at Koala Insulation of East Metro Detroit runs through the same steps:
- Free evaluation. A technician walks the building with you and marks where condensation or heat is causing trouble.
- Assessment. You hear what they found and why they’re recommending a particular foam type and thickness.
- Personalized plan. Scope and schedule get built around your operations. Roof and walls are priced separately.
- Scheduled installation. The work happens in whatever order you agreed on.
- Final walkthrough. You go over the finished work with the team before the job’s closed out.
Frequently Asked Questions
Can you spray foam a metal building while my business stays open?
A lot of the time, yes. We just can’t have people in the area being sprayed, so the job usually gets split into sections or done after closing.
Will spray foam stop my metal building from sweating?
Closed-cell foam does if it’s thick enough. Because it’s stuck right onto the steel, there’s no gap for damp air to sneak into and hit the cold metal.
Open cell or closed cell for a steel building?
Closed cell, nearly every time. Here in Michigan, open-cell lets moisture get back to the steel, and you’d need to add a vapor barrier to stop it.
Will spray foam make a metal building cooler in summer?
Yep. Foam on the roof deck blocks a big share of that afternoon heat, and the floor below is a lot more bearable for it.
Does the foam have to be covered in a commercial building?
Most of the time. If people use the space, expect to need drywall or an approved coating over it. Ask before the job starts, not after.
Ready to Start Saving? Let Koala Insulation Guide You
Before you pick up the phone, do two quick walk-throughs. Go in early on a freezing morning and see where it’s dripping or frosting up, then go back at about 3 p.m. on a scorcher. That’ll show you where the problems are. Book a free estimate with Koala Insulation of East Metro Detroit, and ask for the foam type and thickness in writing along with the work schedule.
Find Your Location
Get a quote